Thursday 8 February 2018

Usage precautions for pentax w1502n



 USAGE PRECAUTIONS 


Surveying instruments are high-precision instruments. In order to assure that the Electronic Total Station W-1500N series product which you have purchased will provide long-lasting maximum performance, the precautions in this manual must be followed. Be sure to follow these instructions and use this product properly at all times.

Solar observation


 WARNING 


Never view the sun directly using the telescope as this may result in loss of sight. Never point the objective lens directly at the sun as this may damage internal components. When using the instrument for solar observation, be sure to attach the special solar filter designed for this product to the objective lens.

[Laser beam]
Do not stare into laser beam. W-1500N series is a Class IIIa (3R) laser product.

 E D M axis 

The W-1500N series EDM is the red visible laser beam and the beam diameter is very small. The beam is emitted from the objective center and the base plate center hole. The EDM axis is designed to coincide with the telescope sight axis but both axes may not sometimes coincide slightly according to the intense temperature change and time lapse.

 Target constant 

Confirm the Target Constant of the instrument before measurement.
If a different constant is to be used, use the correct constant of the target. The constant is stored in the instrument's memory when turned off.

  
Reflector less and reflector sheet


Reflectorless:                                                        
The measurement range and accuracy of Reflectorless are based on the condition that laser beam is emitted perpendicular to the white side of the Kodak Gray Card.
The measurement range may be influenced by the shape of the target and its environment. There is a possibility that the range may vary when the target does not satisfy the conditions above at survey work.

Pay attention to following in case of distance measurement by Reflectorless.
In a situation resulting in low accuracy, perform the distance measurement by Reflector sheet or Prism.

There is a possibility that correct distance measurement may be impossible by dispersion or reduction of laser beam when the laser beam comes into the target from diagonal angle.

There is a possibility that the instrument cannot calculate correctly when receiving reflected
 laser beam from forth and back directions in case of measuring the target on the road.

There is a possibility that synthesized values are calculated and the distance may become longer or shorter than the actual one when the operator measure the target of slope or sphere or rugged shape.

There is a possibility that the instrument cannot calculate correctly by collecting the reflected laser beam from a man or a car that comes and goes in front of the target.

When using Reflector sheet, set the Reflector sheet to have its surface be approx. vertical to the aiming line. If it is positioned not to be approx. right angle, there is a possibility that correct distance measurement may be impossible by dispersion or reduction of laser beam.
In the following environments, the distance might not be able to be measured.
   There is a reflection things (mirror, stainless board and white wall etc.) in the direction of the target     and under too strong sun light.


 Battery & charger 

Never use any battery charger other than the BC05 battery charger as this may result in damage to the instrument.

If water should happen to splash on the instrument or the battery, wipe it off immediately and allow it to dry in a dry location. Do not put the instrument in the case until it is completely dry as this may result in damage to the instrument.

Turn off the power when removing the battery from the instrument as removing the battery while the power is still on may result in damage to the instrument.

The battery mark displayed on the instrument is only an estimate of remaining battery power and is not completely accurate. Replace the battery quickly when it is about to run down as the time a battery lasts on one charge differs depending on conditions of ambient temperature, and the measurement mode of the instrument.

Confirm the battery level remaining before operating.

When the remaining battery power becomes low, a message to alert battery run-out starts coming up. When the message appears, replace the battery to a fully charged one immediately. Running out of battery in middle of use may result in loss of data.  

L.D POINT, laser pointer     

When you make a correct direction using the “LD POINT”, aim the laser beam at the wall and mark the center and then confirm the discrepancy between the reticle center and the marked point beforehand.


Interface

Do not insert or remove USB Connector outdoors.
Be careful not to let dust, mud, sand, water, harmful gas or salty steam enter the card slot or USB connector port.
Be sure to turn the instrument’s power off before inserting or removing the USB Connector.

Touch panel

Use the Stylus pen when you touch the panel for operation of software.

Do not touch the panel with any things such as fingertips or pen point as this may scratch and damage the screen.

No comments:

Post a Comment