PRECAUTIONS REGARDING SAFETY
Safety Precautions (Must be followed)
The following
items are intended to prevent possible injury to the user or other people
and /or damage to the instrument before it occurs. These safety precautions are
important to the safe operation of this product and should be observed at all
times.
Distinctive Displays
The following displays are used to distinguish precautions by
the degree of injury or damage that may result if the precaution is ignored.
WARNING
Items
indicated by this display are precautions which if ignored would result in
serious injury.
CAUTION
Items indicated
by this display are precautions which if ignored may result in injury or
material.
● Here “injury”
refers to injuries such as cuts, burns or electric shock the treatment of
which will not likely require hospitalization or long-term attention.
● “Material damage” refers to damage to facilities, buildings,
acquired data, etc.
Before using
this product, be sure that you have thoroughly read and understood this
instruction manual to ensure proper operation. After reading this manual, be
sure to keep it in a convenient place for easy reference.
This
instrument complies with the protection requirement for residential and
commercial areas. If this instrument is used close to Industrial areas or
transmitters, the equipment can be influenced by electromagnetic
fields.
[ You may like to read
this.!!
WARNING
Do not stare
into the laser beam directly as this may result in damage to your
eyes.
W-1500 N series is a
Class IIIa (3R) laser product.
Do not look into the laser radiation aperture directly as this may result in damage to your eyes.
Never use the telescope to view intense light such as direct sunlight or sunlight reflected through a prism as this may result in loss of sight.
Do not disassemble, modify or repair this product as there a risk of laser radiation.
Do
not aim the laser beam at a person as it is harmful to the eyes and body. Receive the examination treatment by the
doctor when the eyesight or body trouble is doubted by any chance.
● Electro-Magnetic Compatibility (EMC):
This
instrument complies with the protection requirement for residential and
commercial areas. If this instrument is used close to industrial areas or
transmitters, the equipment can be influenced by electromagnetic fields.
● Do not use this
product in a coal mine, in a location where there is coal dust, or near
flammable material as there is a risk of explosion.
● Do not disassemble,
modify or repair this product as there is a risk of fire, electric shock and
burn injury. If you think the product requires repair, contact the retail
outlet where you purchased it or an authorized repair site.
● Only use the BC05
battery charger intended for this product as the battery charger. Use of
another battery charger entails a risk of fire or burn injury from the battery
bursting into flames due to possible differences in voltage or polarity.
● Do not use a
damaged electric cord plug or loose electric outlet when charging as
there is a risk of fire or electric shock.
● Do not charge
the battery while covered by clothes or similar item as there is a risk of
fire if the clothes ignite.
● Do not use the
battery or charger when wet as there is a risk of fire and burn injury due
to short-circuit.
● To prevent
making short-circuit when removing the battery and charger from the case and
storing them, apply electrically resistant tape to the poles of the battery.
Storing the battery and charger as-is may result in fire or burn injury due to
short-circuit.
● Do not throw
the battery into fire or expose it to heat as there is a risk of injury if it
explodes
CAUTION
CAUTION
For safety, please do the opening
inspection and inspection every a fixed period and adjustment.
When the laser beam enters eyes, an
unexpected accident might be caused by the blink of eyes. Establish the laser
product to avoid the height of eyes of a driving person and walker.
Establish an instrument so that laser beam
does not hit a reflection thing as a mirror and a glass window. The refection
beam of the laser is also harmful to the human body.
Besides the time when you measure the
distance, cut off the power supply or shade the beam of aperture with caps.
Keep the laser product in the place where
the person who does not have the product knowledge such as children does not
touch by mistake.
Destroy the power supply mechanism of the
instrument so as not to emit the laser beam at the time of disposal.
● Do not remove the handgrip without good reason. If it does come
off, be sure to attach it securely to the instrument with screws. If it is not
fastened securely, the instrument may fall when you grasp the handgrip, leading
to possible injury.
● Do not short the poles of the battery or charger as there is a
risk of injury or fire.
● Do not touch any fluid which may leak from the battery as there is
a risk of chemical burn injury or reaction.
● Do not insert or remove the electric plug with wet hands as there
is a risk of electric shock.
● Do not use the case to stand on as it is slippery and unstable and
may cause you to fall, resulting in possible injury.
● Be sure the tripod itself and the instrument on the tripod are
both installed securely as insecure installation may cause the tripod to fall
over or the instrument to drop, resulting in possible injury.
● Do not carry the
tripod with the metal shoe pointing toward another person as the person may be
injured if they strike him or her.
● The instrument contains a rechargeable battery and it is
rechargeable.
● At the end of its useful life, it may be illegal to dispose of the
battery.