Pentax W-1502 N
1 Open Total Station
box and pick up Total Station from handle and keep it on tripod and
connect with connecting screw with the
tripod base.
2 Now take batteries
from box and connect with machine (batteries sort is on right side when you
leveling instrument)
3 now click on “Power
button” to start machine.
4 Total Station (automatically
open my Device) if not select automatically my device select it manually.
5 After this
selecting “My Device” Four option will be appear on Total Station Display
1 Fields Genius, 2 Instrument Setup, 3 About, 4 Exits.
Now select first one “1 Fields Genius” and Wait for a 5
seconds.
6 now laser is on
level the instrument on the B.M or STN Point and level whole instrument (leveling,
centering, and focusing) and keep face on Right “right Face” and select à Continue.
7 After leveling the
Instrument Project Manager will come automatically and you can open it
manually, But on the new Project at open automatically.
Now select à “new Project”
Give name -----------
“you can keep name in number or alphabet as you wish” Double click on
name area and give name, you can also give name from keypad.
Change to number Two alphabet click on @ on keypad button to
change it.
Click à
OK à
yes
(Make no change) select à
Continue à
wait for some seconds.
Now Pentax Fields Genius assistant ask you, would you like
to create a new point now?
Click à
yes
_____________________________________________________________________________________
Pentax display appear like this
Store
point
Point ID ____________
Description ____________
Northing ____________
Easting ____________
Elevation ____________
Note tap to enter note “Advanced”
Now click à
“Store Point” machine ask you ‘The description STN is not fond in the AutoMap library,
add to the project file?
Click à
yes (if you enter every time new description or code Total Station will ask you
like this).
8 Now again “Pentax
Fields Genius assistant” ask you, would you like to Setup the Instrument at the
new Point?
Click à
yes
(For new every new project “Pentax Fields Genius assistant”
ask you like this) and assist you on this way.
9 Orientation Setup
Instrument
è
Occupy Point or Station
Point = _____________
Instrument Height = _____________
Bask sight
è
Back sight Point = _____________
è
Back sight Direction = _____________
èBack sight Distance = _____________
è Target manger Click to give prism height
Then Click à
OK
10 now Rotate Total
Station to the Back sight Point and Target it (keep attention here if you make
any mistake this will make you more trouble.
Completing this all click à
“on Right side down click on Total Station icon to take on back sight and Shot.
Displaying
Measuring ………………..
Measuring
angle/distance………….
Now check orientation Result:
Accept à
if all is correct
Observation Again à
if you got Error above 0.020
Cancel à
if you don’t want to setup Instrument.
Watch video Tutorial
Thanks…!